Wireless monitoring for open-pit mines
Connect your pit instruments.
Access readings remotely.
Ackcio Beam acquires readings from supported instruments across benches, ramps and pit walls. Self-Healing Mesh uses alternative communication paths where available as site conditions change.
- Supported instrument interfaces
- Self-Healing Mesh
- Remote access and configuration
Mining deployments
Wireless acquisition.
On the ground.
Open-pit · Botswana
Jwaneng diamond mine
Borehole extensometers and smart cables connect to Ackcio Digital Nodes along a retaining wall. Repeater nodes and a gateway provide the wireless acquisition pathway.
- Instruments
- Borehole extensometers and smart cables
- Acquisition
- Digital nodes, repeaters and gateway
“They are taking away that difficulty, and making it easier to get reliable, real-time data.”Mike Jackson, President & CEO · Ramjack Technology Solutions
From measurement to review
How Ackcio fits your monitoring setup
The instrument output, reading interval, site layout and data destination determine the system configuration.
Match the interface
Connect supported instrument outputs to the appropriate acquisition node. Check the exact sensor model, excitation, output and power needs.
Analogue NodesVibrating Wire NodesDigital NodeCollect the readings
The gateway receives data from the Beam network. Plan its location, power and backhaul around the pit and the required workflow.
Explore the GatewayReview and integrate
Manage the network and sensor data through Snape. Send readings to compatible third-party platforms or your own software using supported API or FTP integrations. Confirm the data format, destination and access requirements for your project.
Explore SnapeWork with the instruments you use
Select the node by the instrument’s electrical output: analogue, vibrating wire or a supported digital interface. The instrument category alone does not determine compatibility.
Check output type, excitation, power, channel requirements and reading interval for each model. Ackcio sensors and compatible third-party instruments can form part of the same monitoring plan.
Fit your existing data workflow
Choose where engineers will review the readings: Snape, a compatible monitoring platform or an internal system. Plan the gateway connection and integration around that destination.
Confirm supported interfaces and data formats with the project team before specifying the system.
The wireless differentiator
Self-Healing Mesh
Pit geometry and site conditions can affect radio links. Ackcio Beam automatically selects communication paths, using alternative routes where available.
Mesh supports radio-path resilience. It cannot repair cut sensor cables, failed instruments or power loss.
How Ackcio Mesh worksChoose the radio system deliberately. Beam Mesh and TM-L LoRa are distinct systems. Confirm the radio, gateway and acquisition requirements for the selected device.
What can you monitor?
Six areas. A connected view.
Keep core measurements in view, then explore the instruments and acquisition requirements for each area.
Monitoring area 01
Weather and blasting
What weather and blasting conditions coincide with the wall’s response?
Relate the wall’s response to rainfall, weather and blasting activity.
- Weather at the pit
- Rainfall, wind and temperature provide environmental context.
- Blast vibration
- Specify suitable vibration instrumentation and acquisition equipment for the required dynamic response.
- Rim and waste-dump response
- Tilt and displacement measurements support assessment of selected locations.
Instruments and measurement considerations
Typical instruments / data
Weather station · Rain gauge · Vibration sensor · Tiltmeter
Weather stations and vibration instruments may be third-party products. Blast vibration needs a verified sensor and acquisition pathway with appropriate bandwidth, sampling rate and synchronisation; it is not supported by every node.
Monitoring area 02
Wall and bench movement
How is displacement changing across the wall and benches?
Track changes at the crest, on benches and through the pit wall.
- Subsurface horizontal displacement
- In-place inclinometers and appropriately installed arrays measure displacement profiles at depth.
- Cracks and joints
- Crackmeters measure relative opening or closing across selected discontinuities.
- Vertical displacement: settlement and heave
- Select settlement sensors or appropriately oriented extensometers for ramps and haul roads. Tiltmeters measure angular change separately.
Instruments and measurement considerations
Typical instruments / data
GeoArray · In-place inclinometer · Tiltmeter · Extensometer · Crackmeter
Tiltmeters measure angular change, not direct displacement or settlement. Select the measurement axis, reference point and installation method for each instrument.
Monitoring area 03
Water and pore pressure
How are pore pressure and water levels changing?
Read water conditions alongside displacement and rainfall.
- Pore water pressure
- Piezometers measure pressure at selected depths behind the pit wall.
- Sumps and dewatering bores
- Suitable water-level instruments record changes in water level.
- Rainfall and drainage
- Review rainfall, pressure and relevant flow measurements together to investigate changing water conditions.
Instruments and measurement considerations
Typical instruments / data
Piezometer · Water-level sensor · Rain gauge · Flow meter
A piezometer measures pressure at its installed location. Correlate readings with rainfall, drainage and displacement; pressure alone does not establish slope stability.
Monitoring area 04
Support and structures
How are instrumented supports and structures responding?
Measure how selected supports and structures respond.
- Rock bolts and anchors
- Suitable load cells measure loads at instrumented support locations.
- Retaining walls and foundations
- Strain gauges measure local strain in ramp retaining walls, crusher bases and conveyor foundations.
- Contact pressure, cracks and tilt
- Pressure cells, crackmeters and tiltmeters address distinct measurements where specified.
Instruments and measurement considerations
Typical instruments / data
Load cell · Strain gauge · Pressure cell · Crackmeter · Tiltmeter
Strain is a local measurement, not a direct stress value. Interpreting loads or structural response requires the installation geometry, calibration and engineering model.
Monitoring area 05
Movement at depth
At which instrumented depths is displacement occurring?
Investigate where displacement occurs through the wall.
- Horizontal displacement profile
- Vertical in-place inclinometers and suitable arrays help locate changes along the borehole.
- Shear zones and weak layers
- Measurements across suspected clay bands or faults provide evidence for engineering interpretation.
- Displacement along a borehole
- Single- and multi-point borehole extensometers measure relative displacement along their installed axes; vertical installations can address settlement and heave.
Instruments and measurement considerations
Typical instruments / data
GeoArray · In-place inclinometer · ShapeArray · Borehole extensometer
Inclinometers and arrays provide displacement profiles; extensometers measure relative displacement along their installed axes. Movement data alone does not identify material properties or prove slope stability.
Monitoring area 06
Data health
Is an unusual reading linked to the ground, the instrument or its data pathway?
Review the measurement and the condition of its data pathway.
- Instrument checks
- Investigate unexpected readings, disconnected sensors and damaged local cables.
- Context for spikes
- Review unusual values alongside blasting, electrical interference and field observations.
- Network and power
- Use available battery, signal and missed-reading information to investigate gaps and connectivity changes.
Instruments and measurement considerations
Typical instruments / data
Battery voltage · Signal strength · Missed readings · Available node and sensor diagnostics
Available diagnostics depend on the device and configuration. Check sensor connections, power and field conditions as well as radio paths when investigating gaps or spikes.
Between readings
A connected record between site visits.
Inspections and surveys remain essential. Automated acquisition adds instrument readings at configured intervals, helping engineers review trends alongside rainfall, blasting and excavation activity.
Reduce routine collection trips
Bring readings from supported instruments to the gateway without visiting each monitoring point for every reading.
Adapt the acquisition layout
Plan node, repeater and gateway positions around changing benches, obstructions and access routes.
Make readings available for review
Connect data collection to a defined review and escalation process, with responsibility for investigating missing or unusual readings.
Start with one asset
Scope the measurements.
Then build the network.
Define the question
Select the wall, ramp or support structure. Specify parameters, measurement locations, reading intervals and engineering responsibilities.
Confirm the pathway
Match instrument outputs, power and acquisition needs to devices. Survey radio routes and agree gateway location, backhaul and commissioning checks.
Validate and extend
Check measurements, network behaviour and the review workflow before expanding to additional locations.
Build a site-specific business case
Compare manual collection effort with instruments, hardware, installation, connectivity and ongoing maintenance. Use the actual site scope and access requirements.
Keep interpretation with the team
Combine readings with inspections, surveys and geological information. The responsible engineers define thresholds and operational responses.
Common questions
Before you specify a system.
Can existing instruments connect to Ackcio?
Check each instrument’s output, excitation, power, channel requirements and reading interval against the supported node interface. Ackcio sensors and compatible third-party instruments can be used within the same monitoring plan.
How does the network handle changing pit layouts?
Nodes select alternative communication paths where available. Survey and revisit the layout as benches, equipment or structures change; adjust node, repeater or gateway positions where required.
Does Mesh remove the need for sensor cables?
The radio network carries readings between nodes and the gateway. Instruments may still connect locally by cable. Mesh cannot repair cable damage, failed instruments or loss of power.
Is TM-L LoRa part of the Beam Mesh network?
TM-L uses LoRa and has a different radio architecture from Beam Mesh. Specify the device and gateway combination for the required workflow; do not assume Mesh routing applies to TM-L.
Can the same node capture ground displacement and blast vibration?
Do not assume it can. Blast vibration has specific bandwidth, sampling and timing requirements. Validate the instrument and acquisition pathway separately from slower geotechnical readings.
Can readings alone demonstrate slope stability?
No. Instrument readings describe measured parameters at specific locations. Interpret them with the geological model, inspections, surveys and engineering assessment.